IGCAdapter correct acceptance of speed record, sync with GDE code
HoTTAdapter2 add support importing ESC1...ESC4
OpenTx refine data parsing
IGCAdapter support up to 7 extension values
IGCAdapter tolerate big time step once if follow on time step smaller 2 sec
correct missing scale synchronisation if measurement name context menu item change
IGCAdapter, uses altitude values as they are, removed use of first altitude value as zero value
OpenTx telemetry, fixed wrong GPS coordinate handling during track display
HoTTAdapter2, added ability to parse ESC turbine extension
add PowerBox Core telemetry log analysis (multi-select log files)
add OpenTx telemetry log analysis (two step analysis)
fix potential NPE in updatehandler
HoTTAdapter2, fix scale synchronization, formatting, unit and factor to support different GPS data source
HoTTAdapter2
- fix missing GAM, EAM, ESC parsing
- parsing North/South hemisphere, as well as East/West of meridian corrected
- correct offset MSL altitude if contained in GPS in *.log
- correct factor home direction, enable translation for HomeDirection
fix iCharger energy calculation
add support iCharger S6, X12
HoTTAdapter2 detecting GPS type to sort and name values
add support for ZeroAdapter (LogView)
fix loading OSD file IGCAdapter
fix Kosmik device properties
fix S32 import capability
fix GeniusWizard import
fix possible error map background
update HoTTAdapter2 handling missing GPS values
correct some scale synchronization references
Copyright Update
update IGCAdapter always calculating speed
update OnLineCommander default speed unit km/h
remove location permission since functional not required
OSD zip entry more resistant against modification
Correction of potential errors when the device is not selected
Adaption to Android level 29
Add support for OnLineCommander
Fix bug in IGCAdapter
Fix bug in map view
Fixed a bug in the record description view
extend HoTT Viewer adapter to handle additional measurements,
update mapbox map implementation,
reduce position related power consumption
fix missing update of data set description tab
HoTTAdapter2 - fix parse sensor values
HoTTAdapter2/3 - reset min/max values while detecting valid values
Migration auf AndroidX, Build-Ziel API 28 beibehalten (Android 9)
Aktualisierung der Jeti-Telemetrie-Rückkanalstatistik
fix file last_modified parsing error using files from DropBox
NMEA-Adapter - synchronize measurement names with PC DE 3.3.7
GPS-Logger* - various improvements, synchronized with PC version 3.3.7
HoTTAdapter2 - fix power calculation while importing *.log EAM
fix loading HoTTViewerAdapter device in context of IGCAdapter
move to MapBox map support, to remove Google Play Services dependencies
correct wording and misspelling, adapt to aktuel requirements
correct some unspecific errors
support JetiAdapter file selection using file browser URI for import
fix Graupner HoTT *.log file parsing ESC data
support R2Prototyping S32 (ESC) and S32_2 (single time line)
fix synchronization problems with scale of measurements with different factor
fix revolution factor Graupner HoTT EAM HoTTAdapter2/3
fix overwritiing while parsing cell voltages Graupner EAM HoTTAdapter2/3
fix ClassCastException while access of class CurveSelectorView
Automatically requesting permissions during runtime used by Android versions >= 6.0Translations to French added with version 1.2.9
With DataEplorer you are able to analyse your log data mobile. It is not a must, but most of the supported file formats are coming from logging devices or telemetry log files generated by radio controlled model sports. Import data log files is supported from already loaded files from your local device storage, extended local storage, cloud storage and USB attached storage. If the device writing log files to a SD-Card it can be attached right away if your mobile device is supporting this.
Data curves can be displayed and configured. Data set comment can be edited to note important events. In case of GPS coordinates availability the corresponding track can be draw using different backgrounds. Curve and maps view allow zooming and a lot of personalisation and configuration. A short help instructions will explain the main functions.
The DataExplorer for Android version is constrained to a single data set in respect of the lower overall resource power provided by mobile computers, like smartphone or tablets. Saved OSD-files can be exchanged between DataExplorer versions. National languages English, Frensh and German are actually available.
Actual supported import data are coming from following devices:
Core-Telemetry (PowerBox) - telemetry data analysis (attention: file multi selection required)
DataVario (WStech) variometer, GPS, multi measurement device
DataVarioDuo (WStech) variometer, GPS, multi measurement device
FlightRecorder (Multiplex) telemetry data logger
Futaba-Telemetry (Robbe/Futaba) telemetry data analyze
GPS-Logger (SM-Modellbau) - GPS, multi measurement device
GPS-Logger2 (SM-Modellbau) - GPS, multi measurement device
GPS-Logger3 (SM-Modellbau) - GPS, multi measurement device
GPXAdapter GPS Exchange Format file analyzer, extensions prepared for Mikrokopter
HoTTAdapter2/3 (Graupner) receiver-, vario-, GPS-, GAM-, EAM-, ESC-sensor module telemetry data
HoTTViewer (Graupner) telemetry data gathered by HoTT Viewer or HoTT Viewer2
iCharger X6 (Junsi) load of CSV charge curves
iCharger X8 (Junsi) load of CSV charge curves
iCharger DX6 (Junsi) load of CSV charge curves
iCharger DX8 (Junsi) load of CSV charge curves
iCharger 308DUO (Junsi) load of CSV charge curves
iCharger 406DUO (Junsi) load of CSV charge curves
iCharger 4010DUO (Junsi) load of CSV charge curves
IGCAdapter (OnLine Contest/International Gliding Commission) file analyzer
IISI Cockpit V2 (Isler) telemetry data analyze
JetiAdapter (Jeti, Jeti-Box) multi sensor telemetry data log
JLog2 (SM-Modellbau) - Kontronik Jive/Castle motor driver logger
Kosmik (Kontronik) motor driver analyze
LinkVario (WStech) variometer, GPS, multi measurement device
LinkVarioDuo (WStech) variometer, GPS, multi measurement device
NMEA-Adapter (diverse) - GPS track analyzer
OpenTx-Telemetry (OpenTx) - telemetry data analysis
Picolario2 (Renschler) - variometer
S32/JLog3 (R2Prototyping) - ESC analyzer
UniLog2 (SM-Modellbau) multi measurement device
PrivacyNotice: The DataExplorer app does not use or transfer personal data to third parties. The DataExplorer app processes log files from the selected device, possibly with position data obtainedf romcontained GPS coordinates to display the path. The log files depend on the selected device and can be in readable text form or binary files. These log files are read and prepared for display. The read/write access to internal and external memory is used to store self created records in DataExplorer's own OSD format and to read own device log files.